NAME

       Write -- send output to serial port

FUNCTION

       This command causes a stream of characters to be written out
the serial port. The number of characters is specified in
io_Length, unless -1 is used, in which case output is sent until
a null(0x00) is encountered.
IO REQUEST
io_Message must have mn_ReplyPort initialized
io_Device set by OpenDevice
io_Unit set by OpenDevice
io_Command CMD_WRITE
io_Flags Set IOF_QUICK to try quick I/O
io_Length number of characters to transmit, or if set
to -1 transmit until null encountered in buffer
io_Data pointer to block of data to transmit

RESULT

       Error -- if the Write succeded, then io_Error will be null.
If the Write failed, then the io_Error will be non-zero.

SEE ALSO

serial.device/SDCMD_SETPARAMS()